Turbo Air TCE066BENX
Turbo Air 5,851 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 1 EC fan motor at 6 FPI, 1118 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE066BENM
Turbo Air 5,851 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 1 EC fan motor at 6 FPI, 1118 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE093BENX
Turbo Air 8,781 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 1 EC fan motor at 6 FPI, 1126 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE093BENM
Turbo Air 8,781 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 1 EC fan motor at 6 FPI, 1126 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE156BENX
Turbo Air 10,695 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 2 EC fan motors at 6 FPI, 2240 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE156BENM
Turbo Air 10,695 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 2 EC fan motors at 6 FPI, 2240 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE175BENX
Turbo Air 14,301 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 2 EC fan motors at 6 FPI, 2252 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE175BENM
Turbo Air 14,301 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 2 EC fan motors at 6 FPI, 2252 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE214BENX
Turbo Air 17,805 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 2 EC fan motors at 6 FPI, 2252 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE214BENM
Turbo Air 17,805 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 2 EC fan motors at 6 FPI, 2252 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE241BENX
Turbo Air 19,735 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 3 EC fan motors at 6 FPI, 3360 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE241BENM
Turbo Air 19,735 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 3 EC fan motors at 6 FPI, 3360 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE288BENX
Turbo Air 21,388 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 4 EC fan motors at 6 FPI, 4480 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE288BENM
Turbo Air 21,388 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 4 EC fan motors at 6 FPI, 4480 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE325BENX
Turbo Air 28,496 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 4 EC fan motors at 6 FPI, 4480 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE325BENM
Turbo Air 28,496 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 4 EC fan motors at 6 FPI, 4480 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
Turbo Air TCE410BENX
Turbo Air 35,613 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 5 EC fan motors at 6 FPI, 5600 CFM. Approved for R448A / R449A; TXV mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) factory mounted.
Turbo Air TCE410BENM
Turbo Air 35,613 BTU/h center mount low velocity unit cooler, electric defrost, 208-230V/60Hz/1Ph. 5 EC fan motors at 6 FPI, 5600 CFM. Approved for R448A / R449A; TXV mounted, solenoid valve mounted. Stocked at Easy Refrigeration Co. in Macon, GA. Call 470-610-0700 or email sales@easyrefrigeration.co for freight and lead time.
Configuration: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted.
About the Turbo Air TCE Center Mount Evaporator Coil
The TCE series is a center mount, low velocity unit cooler with electric defrost. It discharges air in two directions from the middle of the box for gentle, even airflow. Current TCE models are approved for R-448A / R-449A and ship with the expansion valve factory mounted.
Features
- Blue anti-corrosion hydrophobic coated fins
- Inner-groove copper tube for maximum coil efficiency
- Air-pass guard for better efficiency
- TXV and solenoid valve factory mounted (thermostat optional)
- EC fan motors for low energy use
- Electric defrost heaters for low temperature duty
Configuration Options
- NX: R-448A / R-449A expansion valve (TXV) factory mounted
- NM: R-448A / R-449A expansion valve (TXV) and liquid line solenoid valve factory mounted
These R-448A / R-449A versions replace the earlier R-404A OX and OM models.